Removal Procedure
- Remove the transaxle case side cover. Refer to
Control Valve Body Cover Replacement
.
- Remove the TFP switch assembly bolts.
- Remove the TFP switch assembly from the control valve body assembly. The TFP switch O-rings are reusable if not damaged and should remain with the switch assembly.
Installation Procedure
- Inspect the TFP switch assembly in order to verify the condition and correct location of the pressure switch O-rings. If necessary, replace the O-rings.
- Install the TFP switch assembly onto the control valve body assembly and install the bolts.
Tighten
Tighten the control valve body bolts to 12 N·m (9 lb ft).
- Install the transaxle case side cover. Refer to
Control Valve Body Cover Replacement
.
- Start the engine, warm up the transaxle, and check for leaks.
- Check for proper fluid level. Refer to
Transmission Fluid Check
.
Important: It is recommended that transmission adaptive pressure (TAP) information be reset.
Resetting the TAP values using a scan tool will erase all learned values in all cells. As a result, The ECM, PCM or TCM will
need to relearn TAP values. Transmission performance may be affected as new TAP values are learned.
- Reset the TAP values. Refer to
Adapt Function
.