Removal Procedure
- Turn the ignition OFF.
- Disconnect the engine oil pressure (EOP) switch harness connector.
- Remove the EOP switch using a 1 1/6 inch deep well socket.
Installation Procedure
- Apply the RTV sealant, or equivalent, to the EOP switch threads.
Notice: Refer to Fastener Notice in the Preface section.
- Install the EOP switch.
Tighten
Tighten the engine oil pressure switch to 10 N·m
(89 lb in).
- Connect the EOP switch harness connector. Push in the connector until
a click is heard, then pull back to confirm a positive engagement.
- Check the oil level and fill if low.
- Start the engine and check the engine for leaks.