GM Service Manual Online
For 1990-2009 cars only

Object Number: 896232  Size: MF

The heated oxygen sensor (HO2S) bank 1 sensor 2 is threaded into the front exhaust pipe directly behind the cylinder 1, 3, 5 pre-converter (cylinders 1, 3 and 5 are closest to the front of the dash). The sensor is used by the ECM to determine the oxygen storage capability of the pre-converter. The sensor is equipped with a heater element to provide additional heat to speed up sensor activation time. The ECM controls the heater by pulsing circuit 151 to ground. When the heater is commanded Off (circuit not grounded), the voltage level at the ECM should be high (ignition voltage). When the heater is commanded On (circuit grounded), the voltage level at the ECM should be low. The ECM heater feedback circuit uses a pull-up voltage (2.6-4.6 volts), which allows the ECM to individually differentiate between an open, short to ground or short to voltage. DTC P0038 will set if the ECM detects higher than normal feedback voltage when the HO2S bank  1 sensor 2 heater is commanded On with the engine cranking/running.

DTC PARAMETERS

DTC P0038 will set if the HO2S bank 1 sensor 2 heater feedback voltage is greater than 4.6 volts. The heater is commanded On when:

    • The condition exists for longer than 0.5 seconds.
    • The engine speed is greater than 40 RPM.
    • The battery voltage is between 7.5-15.0 volts.

DTC P0038 diagnostic runs continuously once the above conditions have been met.

P0038 is a type B DTC.

DIAGNOSTIC AIDS

Heater element resistance: 7.0-20.2 ohms


Object Number: 898635  Size: FP