COMPLAINT/CONDITION | POSSIBLE CAUSE(S) | CORRECTION(S) |
---|---|---|
Blower Motor Noise/Vibration | Debris in blower | Remove debris. |
Damaged blower motor bearing | Replace blower motor assembly. | |
Blower motor not properly installed | Install blower motor assembly properly into retaining groove. | |
Odor From Air Outlets | Module condensate drain plugged | Remove condensate drain and remove restriction. |
Debris in evaporator case | Remove blower motor assembly and remove debris. | |
Debris trapped in cabin air filter | Replace cabin air filter. | |
Temperature Knob - Difficult to Turn/Binds | Pinched temperature cable | Verify proper routing of cable. |
Cable improperly installed to control head | Verify proper installation. | |
Cable kinked during installation | Replace cable. | |
Cable improperly installed into module adjustment clip | Remove and re-install cable to adjustment clip | |
Debris in control head gears | Remove debris from gears. | |
Temperature/Mode Knobs Limited Rotation | Knob installed improperly | Remove, rotate 180 degrees and re-install |
Recirculation Light Lit - System in Outside Air | System defaults to outside air when defrost or heater/defrost is selected. | Position mode knob to mode other than defrost or heater/defrost. |
A/C Compressor ON - A/C Not Selected | System defaults to A/C ON when defrost or heater/defrost is selected. | Position mode knob to mode other than defrost or heater/defrost. |
A/C Compressor Cycling at Low Ambient | Low ambient evaporator freeze protection software | Normal operation - see ELAP parameters in electronic compressor control section. |
Reduced or Low Airflow from Outlets | Cabin air filter is dirty. | Replace cabin air filter. |