Air conditioning system contains R-134a. This is a chemical mixture which requires special handling procedures to avoid personal injury.
Always wear goggles and wrap a clean cloth around fittings, valves, and connections when performing work that involves opening the refrigerant system. Always work in a well ventilated area and do not weld or steam clean on or near any vehicle-installed air conditioning lines or components.
If R-134a should come in contact with any part of body, flush exposed area with cold water and immediately seek medical help.
All R-134a drums are shipped with a heavy metal screw cap. The purpose of the cap is to protect the valve and safety plug from damage. It is good practice to replace the cap after each use of the drum for this same reason.
If it is necessary to transport or carry any container of R-134a in a vehicle, do not carry it in the passenger compartment.
The refrigerant system may be evacuated and charged using an air conditioning service charging station or a manifold and gage set and a drum of R-134a -- 13.6 kg (30 lb).
Before removing and replacing any of the air conditioning refrigeration lines or components, the R-134a must be completely removed from the system using an approved refrigerant recovery system.
Always use service valve and charging station equipment or pressure gage sets during evacuation and charging procedures.
Notice: Do not connect any line to the high-side service fitting during charging procedure.
The efficient operation and life of the air conditioning system is dependent upon the chemical stability of the refrigeration system. When foreign materials, such as dirt, air, or moisture, contaminate the refrigeration system, they will change the stability of the R-134a and viscosity of refrigerant oil. They will also affect pressure-temperature corrosion and abnormal wear of moving parts.
Adding oil to the A/C system should take place after recovery and before evacuation procedure. Open the A/C system at the suction/liquid line assembly to liquid line joint. Always install new seal washers whenever a joint is opened. Do not lubricate seal washers. Pour the correct quantity of new PAG compressor oil into the liquid line. For component replacement, add new Saturn refrigerant PAG oil to the component before installation.
Saturn air conditioning system requires 220 ml (7.5 oz) of PAG compressor oil. Service compressors have 220 ml (7.5 oz) of PAG oil installed.
With no signs of excessive oil leakage, new oil quantities must be added to system during component replacement and conditions stated as follows:
• | Compressor: Remove, drain, and measure oil. Drain replacement compressor. Add the same amount of new PAG compressor oil drained from removed compressor to replacement compressor. See Compressor section for details. |
• | Evaporator: Add 72 ml (2.4 oz) of new PAG compressor oil. |
• | Condenser: Add 38 ml (1.3 oz) of new PAG compressor oil. |
• | Receiver-Dehydrator: Add 11 ml (0.4 oz) of new PAG compressor oil. |
If the refrigerant charge is abruptly lost due to a large refrigerant leak, hose rupture or collision approximately 132 ml (4.5 oz) of refrigerant oil will be carried out of the system suspended in the refrigerant. Any failure that caused an abrupt refrigerant discharge will cause this oil loss. Conditions that allow the refrigerant to seep or bleed off over time do not cause this oil loss.
Upon replacement of a component which caused a large refrigerant leak, add 132 ml (4.5 oz) of new PAG compressor oil plus the required amount of oil for the particular component, as outlined previously.
Add the oil directly to the replaced component if possible. If the oil cannot easily be added to the replaced part, add the oil to the liquid line, as outlined previously.