Removal Procedure
- Disconnect the pressure transducer
electrical connector.
- Using a back-up wrench to support the refrigerant
line, remove the pressure transducer.
Installation Procedure
Important: Do not use PAG oil.
- Lubricate the pressure port O-ring with mineral oil.
- Hand start the pressure transducer onto the pressure port.
Notice: Refer to Fastener Notice in the Preface section.
- Using a back-up wrench to support the refrigerant line, tighten the pressure
transducer.
Tighten
Tighten the pressure transducer-to-suction/liquid line to 7 N·m
(62 lb in).
- Connect the pressure transducer electrical connector.