Notice: Refer to Fastener Notice in the Preface section.
Tighten
Tighten the door hinge-to-hinge pillar bolts to 30 N·m (22 lb ft).
Tighten
Tighten the door and reinforcement plate-to-hinge nuts to 30 N·m
(22 lb ft).
Tighten
Tighten the door check link-to-body bolt to 10 N·m (89 lb in).