Tools Required
SA9502Z Anti-Static Mat
Removal Procedure
Notice: Failure to use the anti-static mat SA9502Z properly may result in damage to
the cluster electronics.
Important: If the lens/mask gets dirty, it can be cleaned by following the procedures in
the Owner's Handbook.
- Remove instrument panel cluster assembly. Refer to
Instrument Cluster Replacement
.
- Thoroughly clean hands with soap and water to remove any oil or other
substances which could damage the cluster. If unable to clean hands, an alternative
is to wear surgical gloves during all procedures.
Important: It is strongly recommended that rubber gloves (e.g., surgical gloves) be worn
while performing removal and installation procedures to prevent grease, smudges, scratches
and fingerprints.
- Place SA9502Z
Anti-Static Mat down on
the work area. In order to ground the mat, connect the alligator clip to a large metal
object (e.g., work bench) making sure the attaching point is a bare metal surface
and not painted or coated. Also, put the wrist strap around one of your wrists.
- Place a clean, dry, soft material such as a cloth baby diaper on top of
the anti-static mat.
- Place the instrument panel cluster assembly face down on the cloth and
the anti-static mat.
- To remove bulb (1 - 5), rotate the bulb base
1/4 turn counter-clockwise using a 1/4 in. socket or small flat-blade screwdriver.
Installation Procedure
- To replace bulb, rotate the bulb base 1/4 turn counter-clockwise using
a 1/4 in. socket or small flat-blade screwdriver.
- Install the instrument panel cluster assembly. Refer to
Instrument Cluster Replacement
.