Circuit Description
Battery voltage is supplied to the body control module (BCM) by circuit 2540.
This input is internally monitored by the BCM for proper operating voltage. The proper
operating voltage range is from 9-16 volts.
DTC Parameters
The voltage on circuit 2540 is less than 9 volts.
Diagnostic Aids
• | Check for a poor connection at the BCM. Inspect the harness connectors
for backed out terminals, improper terminal mating, broken connector locks, improperly
formed or damaged terminals, and poor terminal-to-wire connection (terminal crimped
over wire insulation and not conductors). |
• | Inspect the wiring harness for damage. Check for broken or chaffed insulation. |
• | If a fault is suspected to be intermittent, wiggling the harness wiring
may help in locating the fault. |