SYMPTOM | PROCEDURE |
---|---|
All blower motor speeds inoperative | Chart 1 |
Blower motor operates in HI speed any time blower switch is activated from Auto | Check for shorted circuit BLU/WHT 761. |
Blower motor operates in HI, but not in an any other speed | Check for shorted PPL CKT 54 at pin 2 of the HVAC Control Module. If no short is found, check circuit BLK 550 for continuity. If continuity is present, faulty Blower Speed Control Module. |
Blower motor operates in all modes except HI | Check for shorted/open circuit BLU/WHT 761. |
No outside or inside air circulation-blower motor functions | Chart 2 |
A/C compressor does not operate or it operates all the time | Refer to manual climate control section of this service manual (chart 6, 8 and 9) |
Mode doors motor not functioning | Chart 3 |
Mix doors motor not functioning | Chart 4 |
Rear defrost feedback circuit malfunction | Chart 5 |