Subject: | Service Manual Update for 2002 L-Series HVAC Service Manuals Regarding Outside Air Temperature Sensor Service Procedure |
Models: | 2002 Saturn L-Series Vehicles equipped with automatic climate control (RPO C68) |
The purpose of this bulletin is to provide a service removal and installation procedure for outside air temperature sensor and update all 2002 HVAC Service Manuals at your location.
Please obtain all 2002 L-Series HVAC Service Manuals and update as indicated below.
1. Copy the reverse side of this bulletin and insert the copied page between pages 282 and 283 of the 2002 HVAC Service Manuals.
Tightening
Tighten the Outside Air Temperature Fastener to 4 N·m (35 lb in).