Circuit Description
Modules connected to the class 2 serial data circuit monitor for serial
data communications during normal vehicle operation. Operating information and commands
are exchanged among the modules. In addition to this, Node Alive messages are transmitted
by each module on the class 2 serial data circuit about once every 2 seconds.
When the module detects one of the following conditions on the class 2 serial
data circuit for approximately 3 seconds, the setting of all other class 2
serial communication DTCs is inhibited and a DTC will set.
DTC
| Condition
|
U1300
| Low voltage on the Class 2 serial data circuit.
|
U1301
| High voltage on the Class 2 serial data circuit.
|
U1305
| Low voltage or high voltage on the Class 2 serial data circuit.
|
Conditions for Running the DTC
• | The voltage supplied to the module is in the normal operating voltage
range. |
• | The vehicle power mode requires serial data communication to occur. |
Conditions for Setting the DTC
• | No valid messages are detected on the Class 2 serial data circuit. |
• | The voltage level detected on the Class 2 serial data circuit is
under one of the following conditions: |
• | The above conditions are met for approximately 3 seconds. |
Action Taken When the DTC Sets
• | The module inhibits the setting of all other Class 2 DTCs. |
• | The module uses default values for all parameters received on the Class 2
serial data circuit. |
Conditions for Clearing the MIL/DTC
• | A current DTC clears when the malfunction is no longer present. |
• | A history DTC clears when the module ignition cycle counter reaches the
reset threshold, without a repeat of the malfunction. |
Diagnostic Aids
• | These DTCs cannot be retrieved with a current status. Diagnosis of current
DTCs is accomplished via the symptom, Scan Tool Does Not Communicate with a Class
2 Device. Refer to Scan Tool Does Not Communicate with Class 2 Device . |
• | An intermittent condition is likely to be caused by a short or an open
on the class 2 serial data circuit. Use the Scan Tool Does Not Communicate
with a Class 2 Device procedure in order to isolate an intermittent condition. Refer
to Scan Tool Does Not Communicate with Class 2 Device . |