Removal Procedure
- Disconnect the refrigerant pressure sensor
electrical connector.
- Using a back-up wrench to support the refrigerant
line, remove the refrigerant pressure sensor.
Installation Procedure
Important: Do not use PAG oil.
- Lubricate the pressure port O-ring with mineral oil.
- Hand start the refrigerant pressure sensor onto the pressure port.
Notice: Refer to Fastener Notice in the Preface section.
- Using a back-up wrench to support the refrigerant line, tighten the refrigerant
pressure sensor.
Tighten
Tighten the refrigerant pressure sensor to 7 N·m (62 lb in).
- Connect the refrigerant pressure sensor
electrical connector.