GM Service Manual Online
For 1990-2009 cars only

Diagnostic Instructions

    • Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
    • Review Strategy Based Diagnosis for an overview of the diagnostic approach.
    •  Diagnostic Procedure Instructions provides an overview of each diagnostic category.

DTC Descriptor

DTC B3265: Trunk/Hatch/Liftglass Release Output Circuit

Diagnostic Fault Information

Circuit

Short to Ground

Open/High Resistance

Short to Voltage

Signal Performance

I/P Fuse Block B+

2

2

--

--

Liftgate Release Switch Signal

B2494

1

--

--

Liftgate Relay Low Reference

--

2

2

--

Liftgate Relay Coil Control

B3265

2

--

--

Liftgate Latch Control

2

2

2

--

Liftgate Latch Ground

--

2

2

--

Liftgate Release Switch Ground

--

1

1

--

1. Liftgate Release Switch Inoperative

2. Liftgate Release Inoperative

Circuit/System Description

The body control module (BCM) provides voltage to the liftgate release relay control circuit thus energizing the L/GATE relay. The energized relay provides voltage to the liftgate latch assembly, releasing the liftgate.

Conditions for Running the DTC

Battery voltage must be between 9-16 volts.

Conditions for Setting the DTC

This DTC will set when the BCM detects a fault in the liftgate latch relay coil control circuit.

Action Taken When the DTC Sets

    • The BCM stores the DTC to memory.
    • The liftgate latch will malfunction.

Conditions for Clearing the DTC

    • This DTC will change from current to history when the fault is no longer present.
    • A history DTC will clear after 100 consecutive ignition cycles if the condition for the malfunction is no longer present.
    • The technician issues a scan tool CLEAR DTCs command.

Reference Information

Schematic Reference

Release Systems Schematics

Connector End View Reference

Vehicle Access Connector End Views

Description and Operation

Rear Hatch/Gate Description and Operation

Electrical Information Reference

    •  Circuit Testing
    •  Connector Repairs
    •  Testing for Intermittent Conditions and Poor Connections
    •  Wiring Repairs

Scan Tool Reference

    •  Scan Tool Data List
    •  Scan Tool Data Definitions

Circuit/System Verification

Command the liftgate release using the liftgate touch pad. The scan tool Liftgate Release Cmd parameter should change between ON and OFF.

Circuit/System Testing

  1. Ignition OFF, disconnect the l/gate relay.
  2. Connect a test lamp between the relay control circuit terminal 69 and B+.
  3. Command the liftgate release ON and OFF using the liftgate touch pad. The test lamp should turn ON and OFF when changing between the commanded states.
  4. If the test lamp is always ON, test the control circuit for a short to ground.
    If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance.
  5. If all circuits test normal, test or replace the BCM.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.