• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
ECT Sensor Signal | P0117 | P0118 | P0118* | P0116, P0128 |
Low Reference | -- | P0118 | P0118* | P0128 |
*ECM or sensor damage may occur if the circuit is shorted to B+ |
Circuit | Short to Ground | Open | Short to Voltage |
---|---|---|---|
Operating Conditions: Engine Operating in Closed Loop Parameter Normal Range: Varies with coolant temperature | |||
ECT Sensor Signal | 150°C (302°F) | -40°C (-40°F) | -40°C (-40°F) |
Low Reference | -- | -40°C (-40°F) | -40°C (-40°F) |
The engine coolant temperature (ECT) sensor is a variable resistor that measures the temperature of the engine coolant. The engine control module (ECM) supplies 5 volts to the ECT sensor signal circuit and supplies a ground for the low reference circuit.
• | The engine run time is greater than 10 seconds. |
OR |
The ignition is ON and the IAT parameter is colder than 90°C (194°F). |
• | The DTC runs continuously when the above condition is met. |
• | The engine is running for greater than 10 seconds. |
OR |
The ignition is ON and the IAT parameter is warmer than 0°C (32°F). |
• | The DTC runs continuously when the above condition is met. |
The ECM detects that the ECT sensor parameter is warmer than 149°C (300°F) for more than 5 seconds.
The ECM detects that the ECT sensor parameter is colder than -39°C (-38°F) for more than 5 seconds.
DTCs P0117 and P0118 are Type B DTCs.
DTCs P0117 and P0118 are Type B DTCs.
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
⇒ | If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If greater than the specified range, test the signal circuit terminal 1 for a short to ground. If the circuit tests normal, replace the ECM. |
⇒ | If less than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ECM. |
Measure and record the resistance of the ECT sensor at various ambient temperatures, then compare those measurements to the Temperature vs Resistance table. Refer to Temperature Versus Resistance .
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for ECM replacement, setup, and programming |