• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
B+, BCM X4 Terminal 2 | B2615 00 | B2615 00 | -- | -- |
B+, BCM X3 Terminal 2 | 3, 4 | 3, 4 | -- | -- |
Courtesy Lamp Control | B2615 00 | 1 | -- | -- |
Courtesy Lamp Defeat Signal | 1 | 5 | -- | -- |
Inadvertent Power Control | B1480 00 | 3 | -- | -- |
Courtesy Lamp Switch ON Signal | 2 | 2 | 1 | -- |
Inadvertent Courtesy Lamps Ground | -- | 1, 3 | -- | -- |
1. Courtesy/Reading Lamps Malfunction 2. Dome Lamp Switch Malfunction 3. Inadvertent Power Courtesy Lamps Malfunction 4. Interior Backlighting Malfunction 5. Courtesy Lamp Defeat Inoperative |
The courtesy lamps are controlled by the body control module (BCM). Inputs from the dome lamp switch and the door ajar switches are monitored by the BCM. When a door ajar switch is closed, or the dome lamp switch is turned to the ON position, the BCM supplies the B+ for the courtesy lamps.
Interior Lighting Systems Description and Operation
Control Module References for scan tool information
⇒ | If the DIC displays the door ajar/liftgate ajar message when a door or the liftgate is closed, refer to Door Ajar Indicator Malfunction. |
⇒ | If the parameter is always Manual Defeat, refer to Courtesy Defeat Switch Malfunction. |
⇒ | If the parameter is Manual, refer to Courtesy Lamps Switch Malfunction. |
⇒ | If one or more of the courtesy lamps remains ON or OFF at all times, refer to Courtesy Lamp Malfunction. |
⇒ | If the test lamp does not illuminate, test the ground circuit for an open/high resistance. |
⇒ | If the parameter is Manual Defeat, test the courtesy defeat signal circuit terminal 9 for a short to ground. If the circuit tests normal, replace the BCM. |
⇒ | If not the specified value, test the signal circuit for an open/high resistance or short to voltage. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp does not illuminate, test the ground circuit for an open/high resistance. |
⇒ | If the parameter is Manual , test the courtesy lamps on signal circuit terminal 12 for a short to ground. If the circuit tests normal, replace the BCM. |
⇒ | If not the specified value, test the signal circuit for an open/high resistance or short to voltage. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal and the circuit fuse is open, test the courtesy lamp control circuits for a short to ground. |
• | Liftgate courtesy lamps - terminal 1 |
• | All other courtesy lamps - terminal B |
⇒ | If the test lamp does not illuminate, test the ground circuit for an open/high resistance. |
• | Liftgate courtesy lamps - terminal 2 |
• | All other courtesy lamps - terminal A |
⇒ | If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for BCM replacement, setup, and programming |