Diagnostic Instructions
DTC Descriptor
DTC C0110 00: Pump Motor Circuit
Diagnostic Fault Information
Circuit
| Short to Ground
| Open/High Resistance
| Short to Voltage
| Signal Performance
|
B+
| C0110 00
| C0110 00
| --
| --
|
Ground
| --
| C0110 00
| --
| --
|
Circuit/System Description
The pump motor is an integral part of the brake pressure modulator valve (BPMV), while the pump motor relay is integral to the electronic brake control module (EBCM). The pump motor relay is not engaged during normal system operation. When the antilock
brake system (ABS) or traction control system (TCS) operation is required the EBCM activates the pump motor relay and turns the pump motor ON.
Conditions for Running the DTC
• | Initialization is complete. |
Conditions for Setting the DTC
• | The EBCM detects a short to ground or an open/high resistance on the B+ circuit. |
• | The EBCM detects an open/high resistance on the ground circuit. |
• | The EBCM detects the pump motor runs continuously. |
• | The EBCM detects the pump motor is binding or stalled. |
Action Taken When the DTC Sets
• | The EBCM disables the ABS/ traction control system (TCS)/ vehicle stability enhancement system (VSES) for the duration of the ignition cycle. |
• | The ABS indicator illuminates. |
• | The Red brake indicator illuminates. |
• | The Stability Control indicator illuminates. |
• | The driver information center (DIC) displays All Wheel Drive OFF, Service Stabilitrak and Service Traction Control messages. |
Conditions for Clearing the DTC
• | The condition for the DTC is no longer present and the ECE 13 response is completed by driving the vehicle at speeds greater than 15 km/h (10 mph) to complete the self test, and the EBCM will turn off the ABS indicator. |
• | The EBCM clears the history DTC when a current DTC is not detected in 100 consecutive drive cycles. |
Reference Information
Schematic Reference
Antilock Brake System Schematics
Connector End View Reference
Component Connector End Views
Description and Operation
ABS Description and Operation
Electrical Information Reference
Scan Tool Reference
Control Module References
for scan tool information
Circuit Verification
Ignition ON, perform the Pump Motor Test with a scan tool and listen/feel the Pump Motor turn ON and OFF.
Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the EBCM.
- Test for less than 1 ohm between the ground circuits listed below and ground.
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
- Ignition ON, verify that a test lamp illuminates between the B+ circuits listed below and ground.
⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal and the B+ circuit fuse is open, replace the BPMV. |
- If all circuits test normal, replace the BPMV/EBCM assembly.
Repair Instructions
Perform the
Diagnostic Repair Verification
after completing the diagnostic procedure.