• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Back Up Lamps Control | B2545 00 | 1 | 2 | -- |
1. Backup Lamps Inoperative 2. Backup Lamps Always On |
When the PRNDL is placed in the REVERSE position, a signal is sent to the body control module (BCM). The BCM then applies voltage through the backup lamps control circuit to the back up lamps. The back up lamps are grounded through G401.
• | The ignition is ON. |
• | The back up lamps must be commanded ON. |
The BCM detects a short to ground on the back up lamp control circuit when the back up lamps are being commanded ON.
The back up lamps do not illuminate.
• | The conditions for setting the DTC are no longer present. |
• | A history DTC clears after 100 malfunction-free ignition cycles. |
Exterior Lighting Systems Description and Operation
Control Module References for scan tool information
Ignition ON, command the Backup Lamps ON with a scan tool. The Backup Lamps parameter should display On and the backup lamps should illuminate.
• | RPO WDA -- terminal 1 |
• | RPO Z88 -- terminal 2 |
• | RPO W49 -- terminal A |
⇒ | If the test lamp illuminates, test the control circuit for a short to ground. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
Control Module References for BCM replacement, setup, and programming