Subject: | EI07200 -- HVAC Performance, A/C Not Cool, A/C Compressor Noise |
Models: | 2007-2008 Buick Enclave |
Attention: | Proceed with this bulletin ONLY if the customer has commented about this concern AND the EI number is listed in GMVIS. If the customer has not commented about this condition or the EI does not show in GMVIS, disregard the bulletin and proceed with
diagnostics found in published Service Information. THIS IS NOT A RECALL -- refer to Service Bulletin 04-00-89-053A for more detail on the use of Engineering Information bulletins. |
Condition
Important: If the customer did not bring their vehicle in for this issue, do not proceed with this bulletin. ONLY CONTACT THE ENGINEER IF DIAGNOSIS LEADS TO AN A/C REPAIR.
Some customers may comment that the vehicle's A/C is not cooling or is not cold enough and/or the A/C compressor is noisy.
Correction
DO NOT REPLACE THE A/C COMPRESSOR.
GM Engineering is attempting to determine the root cause for the concern of A/C not cooling and/or compressor noise. A high percentage of A/C compressors being returned to the Warranty Parts Center (WPC) show no trouble found. Engineering has a need to
gather information on vehicles, PRIOR to repair, that may exhibit this condition. Document the following information on the repair order:
- Does the vehicle currently exhibit the condition(s)? If the condition is for A/C compressor noise, proceed to call Mike Monroe at 248-467-0529 (Cell). Otherwise, continue with step 2.
- Compare the cooling performance to that of another vehicle under the same operating conditions and confirm if the performance is the same or significantly unusual (no cooling performance).
- Perform the A/C System Performance Test according to the procedure listed in SI.
- Record the ambient air temperature displayed on the J-43600.
- Record the high and low side STATIC pressure readings.
- Record the relative humidity and ambient air temperature at the time of the test.
- Record the outlet air temperatures, high side and low side pressures taken while performing the A/C Performance Test.
- What were the results from the A/C Performance Test?
• | System OK - no further repairs required. |
• | A/C Diagnostics Pressure Zone A - proceed with Step 9. |
• | A/C Diagnostics Pressure Zone B - proceed with Step 10. |
• | A/C Diagnostics Pressure Zone C - proceed with Step 11. |
• | A/C Diagnostics Pressure Zone D - proceed with Step 12. |
- If the A/C Performance Test leads to the A/C Diagnostics Pressure Zone A:
• | What was the difference in discharge temperature of the center panel outlets? |
• | Are the A/C system output temperatures good at first, but then turn warm during extended drives? |
• | Was the A/C system found to be undercharged? If so, was a leak test performed and a leak found? |
• | Was the A/C system found to possibly be contaminated? |
• | If the system was evacuated and recharged, are the panel outlet temperatures within specification? |
• | What repair corrected the concern? |
- If the A/C Performance Test leads to the A/C Diagnostics Pressure Zone B:
• | After continued operation of the A/C system, do the low and high side pressures equalize or become static? |
• | Did the A/C system have low refrigerant charge? |
• | Was the AC compressor malfunctioning due to contamination? |
• | What repair corrected the concern? |
- If the A/C Performance Test leads to the A/C Diagnostics Pressure Zone C:
• | Are the cooling fans on and operating properly? |
• | Inspect and note any of the following conditions and make any necessary repairs. |
- | damaged condenser cooling fins |
- | missing or misaligned air baffles |
• | What repair corrected the concern? |
- If the A/C Performance Test leads to the A/C Diagnostics Pressure Zone D, what repair corrected the concern?
• | Were any abrupt drops in temperature detected along the surfaces of these components? |
- | compressor discharge hose |
- | liquid line between the condenser and expansion device. |
• | Was a restriction detected? If so, where? |
• | Was the system leak tested? Any leaks found? If so, where? |
• | What corrected the concern? |
- Immediately contact the following engineer to report the findings ONLY IF A CONDITION IS IDENTIFIED THAT REQUIRES A/C SYSTEM REPAIR. Have all A/C Performance Testing information available when contacting the engineer. If the A/C compressor is suspect,
be prepared with all repair order information.
Engineer
| Phone #
|
Rajat Shah
| 248-635-4663
|
Warranty Information
Select the appropriate labor operation based on the repair made:
Labor Operation
| Description
| Labor Time
|
D9724*
| HVAC -- Engineering Information -- Normal Operation
| 1.2 hrs
|
D9719*
| HVAC -- Engineering Information
| 2.1 hrs
|
* This labor operation number is for bulletin use only. This number will not be published in the Labor Time Guide.
|