• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Mirror Heating Element Supply Voltage | B1640 02 | 1 | B1640 01 | -- |
Low Reference | -- | 1 | 1 | -- |
1. Heated Mirror Malfunction |
The Driver Door Switch (DDS) and Passenger Door Switch (PDS) supply voltage to the outside rearview mirror heater elements upon receipt of a serial data message from the HVAC module indicating that the rear defrost system is active. The door switch supplies B+ through the mirror heating element control circuit when a request is seen. Ground is applied through the mirror heating low reference circuit.
Battery voltage must be between 9-16 volts.
A short to voltage is detected on the mirror heating element supply voltage circuit.
A short to ground is detected on the mirror heating element supply voltage circuit when attempting to activate the heated mirror.
The affected heated mirror will not be activated.
• | A current DTC will clear when the fault is no longer present |
• | A history DTC will clear after 40 malfunction free ignition cycles |
Outside Rearview Mirror Schematics
Outside Mirror Description and Operation
Control Module References for scan tool information
Ignition ON, press the rear window defogger switch. The rear window defogger and both heated mirrors should become warm.
⇒ | If the rear window defogger is inoperative, refer to Rear Window Defogger Malfunction. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. If the circuit tests normal, replace the appropriate door switch. |
⇒ | If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the door switch. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the door switch. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for DDS or PDS replacement, setup and programming |