Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Power Sliding Door Module B+ | B1292, B1395 | B1292, B1395 | -- | -- |
Left/Right Sliding Door Open/Close Switch Signal | 2 | 2 | 2 | -- |
Left/Right Door Enable Switch Signal | 1, 2 | -- | 2 | -- |
Left/Right Sliding Door Latch Motor Control | 1 | 1 | 1 | -- |
Park/Neutral Position Park Signal | -- | 1 | -- | -- |
Left/Right Sliding Door Clutch Control | B1292, B1293, B1294 | B1292, B1293, B1294 | B1293 | -- |
Left/Right Sliding Door Motor Open Control | B1292 | B1292 | B1292 | -- |
Left/Right Sliding Door Motor Close Control | B1292 | B1292 | B1292 | -- |
Left/Right Sliding Door Detent Switch Signal | 1 | B1294 | 1 | -- |
Left/Right Sliding Door Sensor Voltage Reference | 1 | B1395 | 1 | -- |
Left/Right Sliding Door Sensor Low Reference | 1 | B1395 | 1 | -- |
Left/Right Sliding Door Sensor 1 Signal | 1 | B1395 | 1 | -- |
Left/Right Sliding Door Sensor 2 Signal | 1 | B1395 | 1 | -- |
Left/Right Sliding Door Clutch Ground | -- | B1292, B1293, B1294 | 1 | -- |
PSDM Ground | -- | 1 | 1 | -- |
1. Power Sliding Door Malfunction 2. Power Sliding Door Open/Close Switch Inoperative |
The power sliding door (PSD) is designed to stop and reverse direction when an obstruction is present. Proper mechanical operation of the PSD is necessary for power open and close functions to occur.
Manually open and close the PSD slowly in order to determine if the door operates smoothly and without excessive resistance.
• | Clean and lubricate or replace the tracks as necessary. |
• | Inspect for loose guide rollers on the center roller bracket. |
• | Verify proper PSD cable tension |
• | Verify that the door and latches are aligned and operate properly. Refer to Sliding Rear Side Door Adjustment, Rear Side Door Front Edge In/Out Adjustment Rear Side Door Rear Edge In/Out Adjustment and Rear Side Door Up/Down Adjustment |
• | Inspect for misaligned weatherstrips |
Inspect the PSD plungers and corresponding B-Pillar pads for the following conditions:
• | Proper door plunger operation. |
• | Clean electrical contact from the door plungers to the B-pillar pads. |
• | Proper alignment of the door plungers to the B-pillar pads. |
Power Door Systems Connector End Views
Power Sliding Door (PSD) Description and Operation
Ignition ON, observe the scan tool PSD Detent Switch parameter while opening and closing the appropriate power sliding door. The parameter should change between Active and Inactive.
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If not the specified value, test the signal circuit terminals listed below for a short to ground. If the circuits test normal, replace the PSDM. |
• | Terminal E |
• | Terminal F |
• | Terminal E |
• | Terminal F |
⇒ | If not the specified value, test the signal circuits for a short to voltage or an open/high resistance. If the circuits test normal, replace the PSDM. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. If the circuit tests normal, replace the door contact plate. |
⇒ | If not the specified value, test the signal circuit terminal A for a short to ground. If the circuit tests normal, replace the door contact plate. |
⇒ | If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the door contact plate. |
⇒ | If not the specified value, replace the sliding door detent switch. |
⇒ | If greater than the specified range, replace the sliding door detent switch |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for PSDM replacement, programming, and setup |