J 41820 Ball Joint/Stud Separator
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the nuts to 50 N·m (37 lb ft).
Important: Align the cam indicator to the mark on the lower control arm.
Tighten
Tighten the cam nut to 145 N·m (107 lb ft).
Tighten
Tighten the lower ball joint nut to 35 N·m (26 lb ft) plus 130 degrees.