Bosch Connectors BSK
Tools Required
J 44020
Terminal Repair
Kit
Terminal Removal Procedure
- Disconnect the connector from the component.
- Remove the wire dress cover if necessary.
- Push the wire side of the terminal that is being removed toward the connector
and hold it in position.
- Insert the J 38125-561 tool into the 2 cavities on each
side of the terminal at the front of the connector and push until you feel the tool
disengage the terminal retainers. See the release tool cross reference in the Reference
Guide of the
J 44020
Terminal
Repair Kit to ensure that the correct release tool is used.
- Carefully pull the terminal out of the connector. Always remember never
use force when pulling a terminal out of a connector. If the terminal is difficult
to remove, repeat the entire procedure.
Terminal Repair Procedure
Use the appropriate wire assembly repair kits available through Saturn Service
Parts.
Bosch Connectors 2.8 JPT
Tools Required
J 44020
Terminal Repair
Kit
Terminal Removal Procedure
- Pull out the slider on the connector position assurance (CPA) until it
is at the end of its travel.
- Disconnect the connector from the component.
- Remove the wire dress cover if necessary.
- Push the wire side of the terminal that is being removed toward the connector
and hold it in position.
- Insert
the J 42019 (12122378) into the 2 cavities on each side of the terminal
at the front of the connector and push until you feel the tool disengage the terminal
retainers.
- Carefully pull the terminal out of the connector. Always remember never
use force when pulling a terminal out of a connector. If the terminal is difficult
to remove, repeat the entire procedure.
Terminal Repair Procedure
Use the appropriate wire assembly repair kits available through Saturn Service
Parts.
Bosch Connectors 0.64
Tools Required
J 44020
Terminal Repair
Kit
Terminal Removal Procedure
- Locate the lever lock on the wire dress cover. While pressing the lock,
pull the lever over and past the lock until the lever is at the end of its travel.
- Disconnect the connector from the component.
- Pull the rubber boot that covers the wires back to expose the end of the
connector dress cover.
- Place the connector locking lever in the center of the connector.
- Locate the 2 dress cover locking tabs that are on the wire end of the connector.
Insert a small flat-bladed tool between the cover and connector body and pry up.
- Locate the 2 dress cover locking tabs located on the opposite side of the connector.
Insert a small flat-bladed tool between the cover at the connector end and pry up
- Remove the dress cover.
- Cut the tie wrap on the wire bundle.
- Remove the terminal position assurance (TPA) by inserting a small flat-bladed
tool into the small slot in the end of the slider and pushing on the TPA until it
comes out of the connector. When the TPA exits the opposite side of the connector,
gasp the TPA and pull it completely out of the connector.
- Push the wire side of the terminal that is being removed toward the connector
and hold it in position.
- Insert the J 38125-560 (GM P/N 15314260) tool into
the 2 triangular cavities on each side of the terminal at the front of the connector.
See the release tool cross reference in the Reference Guide of the
J-38125
Terminal Repair Kit to ensure that the correct
release tool is used.
- Carefully pull the terminal out of the connector. Always remember never
use force when pulling a terminal out of a connector. If the terminal is difficult
to remove, repeat the entire procedure.
Terminal Repair Procedure
Use the appropriate wire assembly repair kits available through Saturn Service
Parts.
Terminal Replacement Procedure
- Never insert the same terminal back into the connector once it is removed.
Crimp on a new terminal.
- Prior to installation the terminal must be aligned so the coding lugs align
with the coding grooves on the connector.
- Once the terminal is aligned, slide the terminal into the cavity until
the retainer has engaged in the cavity of the connector
- Slide the TPA in the connector body and seat it using a small flat bladed
tool. The TPA is seated when it is flush with the contact housing.
- Secure the wires to the connector body using a tie wrap and replace the
dress cover and grommet.
Bosch Connectors ECM
Special Tools
J-38125
Terminal Repair Kit
Removal Procedure
- Locate the assist lever on the top of the connector. Move the assist lever to the forward position.
- Disconnect the connector from the component.
- Locate the dress cover locking tabs at the corners of the connector. Use a small flat-bladed tool to release the locking tabs and remove the dress cover.
- The terminal positive assurance (TPA) is located in the front of the connector.
- Use a small flat-blade tool to remove TPA from the connector.
- Use the J 38125-213 or the J 38125-556 tool to release the terminals by inserting the tool into the terminal release cavity. See the release
tool cross reference in the Reference Guide of the
J-38125
to ensure that the correct release tool is used.
- While holding the removal tool in place, gently pull the wire out of the back of the connector. Always remember never use force when pulling a terminal out of a connector.
Repair Procedure
Note: Ensure that the dress cover and connector body are both in the released position before reassembling. Failure to do so may cause damage to the connector and component.
Use the appropriate terminal and follow the instructions in the
J-38125
.
Location of the terminal in the repair tray and the proper crimp tool can be found in the appropriate connector end view.