The generator does not require periodic lubrication. The rotor shaft is mounted on bearings. Each bearing contains a permanent grease supply. Periodically check the mounting bolts for tightness, and the drive belt tension. The drive belt is self-adjusting, within the operating limits of the tensioner. Refer to Drive Belt Tensioner Diagnosis in Engine Mechanical - 3.5L for tensioner information.
Important: Service the generator as a complete unit.
Notice: Refer to Fastener Notice in the Preface section.
Tighten
Tighten the bolts to 50 N·m (37 lb ft).
Tighten
Tighten the nut to 30 N·m (22 lb ft).
The generator does not require periodic lubrication. The rotor shaft is mounted on bearings. Each bearing contains a permanent grease supply. Periodically check the mounting bolts for tightness, and the drive belt tension. The drive belt is self-adjusting, within the operating limits of the tensioner. Refer to Drive Belt Tensioner Diagnosis .
Important: Service the generator as a complete unit.
Notice: Refer to Fastener Notice in the Preface section.
Tighten
Tighten the bolts/stud to 50 N·m (37 lb ft).
Tighten
Tighten the nut to 30 N·m (22 lb ft).