Step | Action | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|
Schematic Reference: Interior Lights Schematics Connector End View Reference: Master Electrical Component List | |||||||||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | |||||||
2 | Place the reading lamps in the ON position. Do all the reading lamps illuminate? | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 | ||||||
3 | Are all reading lamps and vanity mirror lamps inoperative? | Go to Step 4 | Go to Step 7 | ||||||
4 | Is the INT/LAMP fuse in the instrument panel (I/P) fuse block open? | Go to Step 5 | Go to Step 6 | ||||||
5 | Test the following circuits for a short to ground:
Refer to Circuit Testing and Wiring Repairs . Did you find and correct the concern? | Go to Step 14 | Go to Step 10 | ||||||
6 | Test the inadvertent power courtesy lamp and battery positive voltage (from the INT/LAMP fuse) circuits for a high resistance or an open. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the concern? | Go to Step 14 | Go to Step 10 | ||||||
7 | Test the inadvertent power courtesy lamp and ground circuits of the inoperative lamp for a high resistance or an open. Did you find and correct the condition? | Go to Step 14 | Go to Step 8 | ||||||
8 | Test the bulb filament for an open. Is the bulb OK? | Go to Step 9 | Go to Step 11 | ||||||
9 | Inspect for poor connections at the harness connector of the reading lamp. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 14 | Go to Step 12 | ||||||
10 | Inspect for poor connections at the harness connector of the body control module (BCM). Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 14 | Go to Step 13 | ||||||
11 | Replace the bulb. Refer to Overhead Console Reading Lamp and Bulb Replacement . Did you complete the replacement? | Go to Step 14 | -- | ||||||
12 | Replace the inoperative reading lamp assembly. Refer to the following: Did you complete the replacement? | Go to Step 14 | -- | ||||||
13 | Replace the BCM. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | Go to Step 14 | -- | ||||||
14 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |