Table 1: | A/C Performance Table |
This test measures the operating efficiency of the A/C system under the following conditions:
• | The current ambient air temperature |
• | The current relative humidity |
• | The high side pressure of the A/C system |
• | The low side pressure of the A/C system |
• | The temperature of the air being discharged into the passenger compartment |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||||||
Are both the low side and high side pressures within the specified value? | More than 16°C (60°F) - 345 kPa (50 psi) More than 24°C (75°F) - 483 kPa (70 psi) More than 33°C (90°F) - 690 kPa (100 psi) | Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Press the RESET button, before using the print function of the J 43600 .
Does all the data recorded fall within the specified ranges of the A/C Performance Table below? | -- | Go to Step 8 | Go to Step 3 | |||||||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the table below? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges, but the panel outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK |
Ambient Temperature | Relative Humidity | Low Side Service Port Pressure | High Side Service Port Pressure | Maximum Left Center Discharge Air Temperature |
---|---|---|---|---|
13-18°C (55-65°F) | 0-100% | 151-220 kPa (22-32 psi) | 578-888 kPa (84-129 psi) | 5°C (41°F) |
19-24°C (66-75°F) | Below 40% | 151-241 kPa (22-35 psi) | 799-1157 kPa (116-168 psi) | 8°C (45°F) |
Above 40% | 165-261 kPa (24-38 psi) | 813-1191 kPa(118-173 psi) | 9°C (48°F) | |
25-29°C (76-85°F) | Below 35% | 192-275 kPa (28-40 psi) | 1061-1378 kPa (154-200 psi) | 10°C (50°F) |
35-50% | 199-282 kPa (29-41 psi) | 1067-1398 kPa (155-203 psi) | 12°C (52°F) | |
Above 50% | 206-296 kPa (30-43 psi) | 1088-1440 kPa (158-209 psi) | 13°C (54°F) | |
30-35°C (86-95°F) | Below 30% | 227-310 kPa (33-45 psi) | 1267-1632 kPa (184-237 psi) | 13°C (55°F) |
30-50% | 234-316 kPa (34-46 psi) | 1288-1667 kPa (187-242 psi) | 14°C (57°F) | |
Above 50% | 241-330 kPa (35-48 psi) | 1322-1729 kPa (192-251 psi) | 15°C (59°F) | |
36-41°C (96-105°F) | Below 20% | 261-351 kPa (38-51 psi) | 1508-1867 kPa (219-271 psi) | 17°C (61°F) |
20-40% | 268-351 kPa (39-51 psi) | 1529-1929 kPa (222-280 psi) | 18°C (63°F) | |
Above 40% | 275-358 kPa (40-52 psi) | 1570-1977 kPa (228-287 psi) | 18°C (64°F) | |
42-46°C (106-115°F) | Below 20% | 310-385 kPa (45-56 psi) | 1770-2087 kPa (257-303 psi) | 19°C (66°F) |
Above 20% | 310-385 kPa (45-56 psi) | 1791-2149 kPa (260-312 psi) | 20°C (68°F) | |
47-49°C (116-120°F) | Below 30% | 344-420 kPa (50-61 psi) | 2011-2342 kPa (292-340 psi) | 23°C (72°F) |
Table 1: | A/C Performance Table |
This test measures the operating efficiency of the A/C system under the following conditions:
• | The current ambient air temperature |
• | The current relative humidity |
• | The high side pressure of the A/C system |
• | The low side pressure of the A/C system |
• | The temperature of the air being discharged into the passenger compartment |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||||||
Are both the low side and high side pressures within the specified value? | More than 16°C (60°F) - 345 kPa (50 psi) More than 24°C (75°F) - 483 kPa (70 psi) More than 33°C (90°F) - 690 kPa (100 psi) | Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Press the RESET button, before using the print function of the J 43600 .
Does all the data recorded fall within the specified ranges of the A/C Performance Table below? | -- | Go to Step 8 | Go to Step 3 | |||||||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the table below? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges, but the panel outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK |
Ambient Temperature | Relative Humidity | Low Side Service Port Pressure | High Side Service Port Pressure | Maximum Left Center Discharge Air Temperature |
---|---|---|---|---|
13-18°C (55-65°F) | 0-100% | 151-206 kPa (22-30 psi) | 909-1322 kPa (132-192 psi) | 5°C (41°F) |
19-24°C (66-75°F) | Below 40% | 151-213 kPa (22-31 psi) | 957-1371 kPa (139-199 psi) | 5°C (41°F) |
Above 40% | 158-227 kPa (23-33 psi) | 1081-1502 kPa (157-218 psi) | 8°C (45°F) | |
25-29°C (76-85°F) | Below 35% | 165-227 kPa (24-33 psi) | 1198-1522 kPa (174-221 psi) | 8°C (45°F) |
35-50% | 172-234 kPa (25-34 psi) | 1267-1570 kPa (184-228 psi) | 8°C (45°F) | |
Above 50% | 179-241 kPa (26-35 psi) | 1322-1646 kPa (192-239 psi) | 8°C (46°F) | |
30-35°C (86-95°F) | Below 30% | 186-248 kPa (27-36 psi) | 1391-1722 kPa (202-250 psi) | 9°C (48°F) |
30-50% | 186-254 kPa (27-37 psi) | 1433-1770 kPa (208-257 psi) | 10°C (50°F) | |
Above 50% | 192-254 kPa (28-37 psi) | 1488-1832 kPa (216-266 psi) | 10°C (50°F) | |
36-41°C (96-105°F) | Below 20% | 206-261 kPa (30-38 psi) | 1598-1922 kPa (232-279 psi) | 12°C (52°F) |
20-40% | 206-268 kPa (30-39 psi) | 1619-1949 kPa (235-283 psi) | 13°C (54°F) | |
Above 40% | 206-268 kPa (30-39 psi) | 1660-1977 kPa (241-287 psi) | 13°C (54°F) | |
42-46°C (106-115°F) | Below 20% | 227-282 kPa (33-41 psi) | 1818-2101 kPa (264-305 psi) | 13°C (55°F) |
Above 20% | 227-282 kPa (33-41 psi) | 1839-2122 kPa (267-308 psi) | 13°C (55°F) | |
47-49°C (116-120°F) | Below 30% | 241-296 kPa (35-43 psi) | 2018-2287 kPa (293-332 psi) | 15°C (59°F) |