Problems associated with refueling the vehicle such as premature shutoffs of the fill nozzle or inability to dispense fuel at a high rate are related to 2 areas:

    • A blocked inlet (i.e., the fill pipe)
        OR
    • The primary vent path is blocked or severely restricted.

Redesign of the fuel fill inlet and vent path was done as a result of Onboard Refueling and Vapor Recovery (ORVR) requirements.

Diagnostic Aids

Symptoms of a blocked inlet path will include:

    • An inability to dispense fuel at anything above a trickle rate, if that.
        Fuel evident at fill head.
    • Nozzle shutting off virtually immediately, since no volume of fuel can be dispensed.
        Suspect a stuck inlet check valve. Check for operation with siphon hose.

Symptoms of a blocked/restricted vent path include:

    • A premature shutoff of fill nozzle at medium to high flow rates.
    • Nozzle shutting off after dispensing only 0.8-1.1 L (0.2-0.3 gallons). May be less with higher temperatures and/or higher RVP fuels. After a few seconds of waiting, this process can be repeated.
    • Connect the scan tool and look for DTCs P0446 or P0449.
    • Verify vent path during refueling. Connect the scan tool and go into enhanced evaporative emission (EVAP) tests to control vent solenoid and read fuel tank pressure sensor.
       - Normal sensor voltage is 1.4-1.6 volts. It will decrease with rising tank pressure (during refueling) and during refueling will stabilize just below 1 volt.
       - If voltage drops rapidly below this value towards 0.2-0.3 volts during refueling, this is indication that the major vent path is blocked.
       - Check vent path from EVAP vent solenoid backwards to isolate problem component (vent solenoid, vent pipe/hose, canister, fill limit vent valve (FLVV), etc.)