SA9401C Generator Output Stud Wrench
Caution: Ensure that the vehicle is properly supported and squarely positioned. To help avoid personal injury when a vehicle is on a hoist, provide additional support for the vehicle on the opposite end from which the components are being removed.
Notice: Failure to hold the stud when loosening the lock nut may crack the plastic insulator and cause the generator to fail.
Notice: Refer to Fastener Notice in the Preface section.
Notice: The generator shield must be installed to prevent premature generator failures due to foreign debris intrusion.
Tighten
Tighten the generator bolts to 32 N·m (24 lb ft).
Notice: Failure to hold stud when tightening lock nut may crack plastic insulator and cause generator to fail.
Important: The battery terminal fusible link wire (between the starter and generator) should be orientated on the generator between 10 and 11 o'clock position.
Tighten
Tighten the generator positive terminal to 10 N·m (89 lb in).
Tighten
Tighten the wheel nuts to 140 N·m (103 lb ft).
Tighten
Tighten the battery terminal bolts to 17 N·m (13 lb ft).