Important: Note which spark plug wire is removed from which coil tower. The spark plug wires must be connected to the correct coil towers.
Notice: Refer to Fastener Notice in the Preface section.
Notice: Verify the threads of the bolts, mounting surface, and thread holes are clean and free of any residue.
Use care when installing the EI module bolts. Make sure the bolt head is seated on the EI module when the torque specification is reached. If the bolt head is not seated on the ignition module, remove the bolt and tap the hole to clean any debris from the threads. Over torquing of the EI module will result in cracking the coil housing and damaging the coil.Tighten
Tighten the EI module bolts to 8 N·m (71 lb in).
Tighten
Tighten the EI module bolts to 8 N·m (71 lb in).
Important: Orientation of the wires to the EI module is critical to the operation of both the module and On-board diagnostics. The orientation from left to right is (4) (1) (2) (3).