Tools Required
SA9149AC-7 Core Valve Replacer
Removal Procedure
- Discharge the refrigerant system using an approved refrigerant recovery system.
- Remove the valve core using the Core Valve Replacer SA9149AC-7
.
Installation Procedure
- Install and tighten the valve core using SA9149AC-7
Core Valve Replacer.
Notice: To prevent loss of refrigerant charge, make sure to install and tighten cap.
Replace cap if seal is missing or damaged.
- Evacuate, charge, and leak test the A/C system.