Removal Procedure
- Remove the lower
trim panel from the lift gate.
- Disconnect the electrical connector.
- Disconnect the lock cable from the latch.
- Remove the latch to lift gate fasteners.
- Remove the latch.
Installation Procedure
- Position the latch on the lift gate.
Notice: Refer to Fastener Notice in the Preface section.
- Install the latch with the fasteners.
Tighten
Tighten the lift gate latch-to-lift gate fasteners to 10 N·m (89 lb in).
- Connect the lock cable.
- Connect the electrical connector.
- Replace the lift gate lower trim panel.