The numbers below refer to the step numbers on the diagnostic table.
This tests for A/C compressor engagement. Ambient air temperature must be above 5°C (40°F) for the compressor to engage.
This tests for the blower motor functionality.
This tests if the A/C compressor function is inoperative.
Step | Action | Yes | No | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The temperature cannot be adjusted, or the cooling is insufficient during A/C operation. | |||||||||||||
1 | Did you perform the HVAC Diagnostics System Check? | Go to Step 2 | |||||||||||
Important: The ambient air temperature must be above 5°C (40°F).
Does the A/C compressor operate? | Go to Step 3 | ||||||||||||
Does the blower motor operate in any of the speed positions? | Go to Step 4 | Go to Blower Motor Inoperative | |||||||||||
4 | Does the blower motor operate at the desired speeds? | Go to Step 5 | Go to Blower Motor Malfunction | ||||||||||
5 |
Does the recirculation door move to the recirculation position? | Go to Step 6 | |||||||||||
When the A/C is ON, does the customer concern occur? | Go to Step 7 | Go to Step 8 | |||||||||||
7 | Perform the refrigerant system performance test. Refer to Air Conditioning (A/C) System Performance Test in Heating, Ventilation and Air Conditioning. Did you find and correct the condition? | Go to Step 9 | Go to Step 8 | ||||||||||
8 | Inspect the air temperature door and linkage for the following conditions:
Did you find and correct the condition? | Go to Step 9 | Go to High or Low Temperature Control Effort in Heating, Ventilation and Air Conditioning | ||||||||||
9 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |