Modules connected to the low speed GMLAN serial data circuit monitor for serial data communications on the low speed GMLAN network during normal vehicle operation. Operating information and commands are exchanged among the modules.
The following modules communicate on low speed GMLAN:
• | Radio, w/U32 |
• | Digital Radio Receiver (DRR), w/U2K |
The following conditions may cause a total loss of low speed GMLAN data communication:
• | The low speed GMLAN serial data circuit is shorted to ground. |
• | The low speed GMLAN serial data circuit is shorted to voltage. |
• | An internal malfunction of a module on the low speed GMLAN network that causes a short to voltage or ground. |
Step | Action | Yes | No | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: Data Link Connector Schematics Connector End View Reference: Master Electrical Component List in Wiring Systems | |||||||||||||||||||||||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | Go to Diagnostic System Check - Vehicle in Vehicle DTC Information | ||||||||||||||||||||
2 |
Important: Make sure the CANdi module works fine. When functioning properly, CANdi's LED flashes. In the event of a problem, the LED will be constantly illuminated.
Does the scan tool communicate with all modules on the GMLAN serial data circuits? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 | ||||||||||||||||||||
3 |
Refer to the following:
Did you find and correct the condition? | Go to Step 9 | Go to Step 4 | ||||||||||||||||||||
4 |
Does the scan tool communicate with the module? | Go to Step 5 | Go to Step 6 | ||||||||||||||||||||
5 | If the vehicle is equipped with two modules on low speed GMLAN serial data circuit, consider the disconnected module the non communicating one for the next step. Is the vehicle equipped with two modules on low speed GMLAN? | Go to Step 6 | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | ||||||||||||||||||||
6 |
Refer to the following:
Did you find and correct the condition? | Go to Step 9 | Go to Step 7 | ||||||||||||||||||||
7 | Inspect for poor connections and terminal tension at the following harness connector circuits of the module that is not communicating:
Refer to the following:
Did you find and correct the condition? | Go to Step 9 | Go to Step 8 | ||||||||||||||||||||
8 | Replace the module that is not communicating on the low speed GMLAN serial data circuit. Refer to Control Module References for replacement, setup and programming. Did you complete the replacement? | Go to Step 9 | -- | ||||||||||||||||||||
9 |
Does the scan tool communicate normally with the modules on low speed GMLAN bus? | System OK | Go to Step 2 |