- Install the spring (413) and valve (414). The valve must move freely
in the bore.
Notice: Refer to Fastener Notice in the Preface section.
- Install the NEW O-ring (415), solenoid (416) and bolts (417).
Tighten
Tighten the bolts to 12 N·m (106 lb in).
- Install a NEW O-ring (418).
- Install the module (412) and bolts (436).
Tighten
Tighten the bolts to 22 N·m (16 lb ft).
- Install 2 M20 x 1.5 mm nuts onto the fitting (411).
- Install the fitting (411), if required.
Tighten
Tighten the fitting to 49 N·m (36 lb ft).
- Remove the 2 M20 x 1.5 mm nuts from the fitting.
- Install a NEW O-ring (440) and switch (437).
Tighten
Tighten the switch to 22 N·m (16 lb ft).