Removal Procedure
- Remove the air cleaner outlet duct. Refer to
Air Cleaner Outlet Duct Replacement.
- Disconnect the engine wiring harness electrical connectors (2, 3) from the appropriate camshaft position (CMP) actuator solenoid valve.
- Remove the exhaust (1) CMP actuator solenoid valve bolt and valve, if required.
- Remove the intake (2) CMP actuator solenoid valve bolt and valve, if required.
- Inspect the solenoid valve O-ring seals for damage, replace as necessary.
Installation Procedure
Notice: Refer to Fastener Notice in the Preface section.
- Lubricate the solenoid valve O-ring seals with clean engine oil.
- Install the intake (2) CMP actuator solenoid valve and bolt, if required.
Tighten
Tighten the bolt to 10 N·m (89 lb in).
- Install the exhaust (1) CMP actuator solenoid valve and bolt, if required.
Tighten
Tighten the bolt to 10 N·m (89 lb in).
- Connect the engine wiring harness electrical connector (2, 3) to the appropriate CMP actuator solenoid valve.
- Install the air cleaner outlet duct. Refer to
Air Cleaner Outlet Duct Replacement.