GM Service Manual Online
For 1990-2009 cars only

Removal Procedure

Caution: To help avoid personal injury, be careful when working in the vicinity of the generator battery disconnect control module. Internal components will still be live, 36V potential, even when the cover has been opened or removed.


    Object Number: 1831461  Size: SH
  1. Disconnect the hybrid battery. Refer to Hybrid Battery Service Disconnect/Connect .
  2. Remove the plastic nut (1) from the 36-volt negative battery cable lead.
  3. Remove the 36-volt negative battery cable lead from the generator battery.

  4. Object Number: 1831800  Size: SH
  5. Remove the generator battery fuse (1) from the negative battery stud.

  6. Object Number: 1820195  Size: SH
  7. Remove and discard the 36-volt positive battery cable lead nut (6).
  8. Remove the 36-volt positive battery cable lead (5).
  9. Remove the cable shield lead nut (3) and cable lead (4).
  10. Secure the cables out of the way, ensuring that the cables CANNOT be re-installed without your knowledge.

  11. Object Number: 1831947  Size: SH
  12. Remove the 2 generator battery fan bolts (2).
  13. Remove the 12 generator battery cover bolts (1).
  14. Remove the generator battery wiring harness from the clip (3) on the generator battery cover.

  15. Object Number: 1831948  Size: SH
  16. Remove the generator battery cover.

  17. Object Number: 1864889  Size: SH

    Important: Removing the interconnect cables will disable the 36 volts within the generator battery control module.

  18. Remove the generator battery terminal covers (1).
  19. Remove the generator battery cable nuts (2).
  20. Remove the generator battery cable leads (3, 4, and 5) from the batteries.
  21. Remove the 3 small wire terminal leads located under the battery cable leads from the batteries.

  22. Object Number: 1831950  Size: SH
  23. Remove the generator battery control module nut (4), and the battery cable (3) from the stud.
  24. Remove the generator battery control module nut (8), and the battery cable (7) from the stud.

  25. Object Number: 1831951  Size: SH
  26. Disconnect the wiring harness electrical connector (1) from the vent fan electrical connector.
  27. Remove the vent fan wiring harness from the wire retainer.
  28. Disconnect the generator battery temperature sensor wiring harness electrical connectors (2, 5) from the generator control module.
  29. Reposition the battery cables and the generator battery temperature sensor wiring harness out of the way.

  30. Object Number: 1831952  Size: SH
  31. Disconnect the generator battery control module pigtail electrical connector located just under the left quarter lower trim panel.
  32. Remove the generator battery control module pigtail from the clip on the side of the battery carrier.
  33. Remove the 4 generator battery control module bolts.
  34. Remove the generator battery control module.

Installation Procedure


    Object Number: 1831952  Size: SH
  1. Install the generator battery control module.
  2. Notice: Refer to Fastener Notice in the Preface section.

  3. Install the 4 generator battery control module bolts.
  4. Tighten
    Tighten the bolts to 8 N·m (71 lb in).

  5. Connect the generator battery control module pigtail electrical connector located just under the left quarter lower trim panel.
  6. Install the generator battery control module pigtail to the clip on the side of the battery carrier.

  7. Object Number: 1831951  Size: SH
  8. Position the generator battery temperature sensor wiring harness and the battery cables to the generator control module.
  9. Connect the generator battery temperature sensor wiring harness electrical connectors (2, 5) to the generator control module.
  10. Connect the wiring harness electrical connector (1) to the vent fan electrical connector.
  11. Install the vent fan wiring harness to the wire retainer.

  12. Object Number: 1831950  Size: SH
  13. Ensure that the generator battery temperature sensor wiring harness terminals (5, 6) and installed on the generator battery control module studs.
  14. Install the battery cable (7), and the generator battery control module nut (8) to the stud.
  15. Tighten
    Tighten the nut to 8 N·m (71 lb in).

  16. Install the battery cable (3), and the generator battery control module nut (4) to the stud.
  17. Tighten
    Tighten the nut to 8 N·m (71 lb in).


    Object Number: 1864889  Size: SH
  18. Install the 3 small wire terminal leads to the batteries.
  19. Install the generator battery cable leads (3, 4, and 5) to the batteries.
  20. Install the generator battery cable nuts (2).
  21. Tighten
    Tighten the nut to 8 N·m (71 lb in).

  22. Install the generator battery terminal covers (1).

  23. Object Number: 1831948  Size: SH
  24. Install the generator battery cover.

  25. Object Number: 1831947  Size: SH
  26. Install the 12 generator battery cover bolts (1).
  27. Tighten
    Tighten the bolts to 8 N·m (71 lb in).

  28. Install the 2 generator battery fan bolts (2).
  29. Tighten
    Tighten the bolts to 8 N·m (71 lb in).

  30. Install the generator battery wiring harness to the clip (3) on the generator battery cover.

  31. Object Number: 1820195  Size: SH
  32. Install the cable shield lead (4) and nut (3).
  33. Tighten
    Tighten the nut to 9 N·m (18 lb in).

  34. Install the 36-volt positive battery cable lead (6) to the generator battery.
  35. Install a NEW 36-volt positive battery cable lead nut (6). Start the nut finger tight, and then torque to the specification given.
  36. Tighten
    Tighten the nut to 15 N·m (11 lb ft).


    Object Number: 1831800  Size: SH
  37. Install the generator battery fuse (1) to the negative battery stud.

  38. Object Number: 1831461  Size: SH

    Important: Position the plastic nut to the negative battery cable and ensure that the nipple is inserted to the terminal prior to installing the negative cable to the generator battery, Otherwise damage to the nut may occur.

  39. Position the plastic nut (1) to the 36-volt negative battery cable lead ensuring that the nipple on the plastic nut is inserted through the hole in the terminal.
  40. Install the 36-volt negative battery cable lead and nut to the generator battery.
  41. Tighten
    Tighten the nut to 10.7 N·m (95 lb in).

  42. Connect the hybrid battery. Refer to Hybrid Battery Service Disconnect/Connect .