Removal Procedure
- Disconnect the hybrid connect. Refer to
Hybrid Battery Service Disconnect/Connect.
- Remove the 2 generator battery vent fan cover bolts (2).
- Remove the 12 generator battery cover bolts (1).
- Remove the generator battery cover (1).
Important: Removing the interconnect cables will disable the 36 volts within the generator battery control module.
- Remove the generator battery terminal rubber cups.
- Remove the generator battery cable nuts.
- Remove the 36-Volt battery internal cable (1) from the battery.
Installation Procedure
- Install the 36-Volt battery internal cable (1) to the battery.
Caution: Refer to Fastener Notice in the Preface section.
- Install the generator battery cable nuts.
Tighten
Tighten the bolt to 8 N·m(71 lb in)
- Install the generator battery terminal rubber cups.
- Install the generator battery cover (1).
- Install the 12 generator battery cover bolts (1).
Tighten
Tighten the bolts to 8 N·m(71 lb in)
- Install the 2 generator battery vent fan cover bolts (2).
Tighten
Tighten the bolts to 8 N·m(71 lb in)
- Connect the hybrid disconnect. Refer to
Hybrid Battery Service Disconnect/Connect.