Removal Procedure
- Remove the left side insulator/closeout panel. Refer
to
Instrument Panel Insulator Panel Replacement - Left Side .
- Disconnect the electrical connector from the floor actuator.
- Remove the floor actuator screws from the HVAC module.
- Remove the floor actuator from the HVAC module.
Installation Procedure
- Align the floor actuator with the door shaft and rotate
into position.
Notice: Refer to Fastener Notice in the Preface section.
- Install the floor actuator screws to the HVAC module.
Tighten
Tighten the screws to 1 N·m (9 lb in).
- Connect the electrical connector to the floor actuator.
Important: Any time a mode actuator or the HVAC control
module is replaced, the HVAC control module must be calibrated to ensure proper air
distribution.
- Calibrate the mode actuators by simultaneously pushing the A/C and RECIRC buttons
on the HVAC control module three times each, within two seconds of initial push.
• | The A/C and RECIRC button LEDs will flash while this calibration is taking
place. |
• | The calibration will take anywhere between 10 to 30 seconds depending
on battery voltage. |
• | The LEDs will quit flashing when the calibration is complete. |
- Cycle the ignition and verify proper operation.
- Install the left side insulator/closeout panel. Refer to
Instrument Panel Insulator Panel Replacement - Left Side.