Air Conditioning (A/C) Refrigerant Pressure Sensor Replacement for Saturn VUE - AWD 2007
Air Conditioning (A/C) Refrigerant Pressure Sensor Replacement L61/L66
Removal Procedure
- Raise and support the vehicle. Refer to
Lifting and Jacking the Vehicle
.
- Disconnect the electrical connector from the refrigerant pressure sensor.
- Remove the refrigerant pressure sensor from the compressor hose.
Installation Procedure
Important: Use R-12 refrigerant oil (mineral) to lubricate O-rings. Use of R-134a (PAG) oil will cause premature corrosion of fitting joints.
- Lubricate the refrigerant pressure sensor O-ring with mineral oil. Refer to
O-Ring Replacement
.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Hand start the refrigerant pressure sensor to the compressor hose, taking care not to pinch the O-ring and tighten.
Tighten
Tighten the pressure sensor to 10 N·m (89 lb in).
- Install the electrical connector to the refrigerant pressure sensor.
- Lower the vehicle.
Air Conditioning (A/C) Refrigerant Pressure Sensor Replacement LAT
Callout
| Component Name
|
Preliminary ProcedureRemove the left headlamp assembly. Refer to
Headlamp Assembly or Headlamp Bulb and/or Cornering, Sidemarker, Park, Turn Signal Bulb Replacement
|
1
| Refrigerant Pressure Sensor
Procedure
| • | Disconnect the electrical connector from the refrigerant pressure sensor. |
| • | Hand start the refrigerant pressure sensor to the receiver dehydrator, taking care not to pinch the O-ring and tighten. |
Tighten 4 N·m (35 lb in) |
2
| O-ring
Procedure
| • | Lubricate the new refrigerant pressure sensor O-ring with mineral oil. Refer to
O-Ring Replacement |
| • | Remove and discard the O-ring. |
|