GM Service Manual Online
For 1990-2009 cars only

Removal Procedure


    Object Number: 1284985  Size: SH
  1. Remove the right side insulator/closeout panel. Refer to Instrument Panel Insulator Panel Replacement - Right Side.
  2. Disconnect the electrical connector from the recirculation actuator.
  3. Remove the recirculation actuator screws from the HVAC module.
  4. Remove the recirculation actuator from the HVAC module.

Installation Procedure


    Object Number: 1284985  Size: SH
  1. Align the recirculation actuator with the door shaft and rotate into position.
  2. Notice: Refer to Fastener Notice in the Preface section.

  3. Install the recirculation actuator screws to the HVAC module.
  4. Tighten
    Tighten the screws to 1 N·m (9 lb in).

  5. Connect the electrical connector to the recirculation actuator.
  6. Cycle the ignition and verify proper operation.
  7. Install the right side insulator/closeout panel. Refer to Instrument Panel Insulator Panel Replacement - Right Side .