• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
The starter/generator control module (SGCM) monitors connector C2 terminals 15 and 16. When the connector is disconnected, the SGCM capacitors are electrically connected to a discharge resistor.
The engine is running.
36-volt output voltage greater than 10 volts and discharge resistance error signal is ON for 1 second.
Hybrid system is disabled.
Clears 30 seconds after cycle wakeup signal.
Possible cable open or SGCM internal problem.
Hybrid Controls Connector End Views
Caution: To help avoid personal injury, additional precautions must be taken prior to working on the generator control module or the generator starter. After removing the 36V battery cables from the generator battery, remove both engine wiring harness connectors from the generator control module. Wait at least 5 minutes and then remove the generator control module cover. Verify voltage levels at all 36V, 12V, and 3-phase connections, are less than 3 volts using a DMM before proceeding.
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
Control Module References for SGCM replacement, setup, and programming.