• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
The starter/generator control module (SGCM) monitors the hybrid battery voltage sense circuit low and circuit high to detect the failure of the 36-volt output voltage sensor circuit below or above a valid range.
The engine is running.
• | Sensor signal is less than 0.2 volt for continuous 20 ms . |
• | Sensor signal is less than 0.2 volt for 20 ms and 36-volt battery voltage is greater than 5 volts for 20 ms. |
Sensor output voltage less than 4 volts and 36-volt battery voltage is greater than 5 volts for 20 ms.
• | Stop PWM (MGU shutdown). |
• | APM PWM off. |
Closes 30 seconds after cycle wake up signal.
Possible sensor short to ground.
Possible short to voltage or open.
Hybrid Controls Connector End Views
Caution: To help avoid personal injury, additional precautions must be taken prior to working on the generator control module or the generator starter. After removing the 36V battery cables from the generator battery, remove both engine wiring harness connectors from the generator control module. Wait at least 5 minutes and then remove the generator control module cover. Verify voltage levels at all 36V, 12V, and 3-phase connections, are less than 3 volts using a DMM before proceeding.
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
Control Module References for SGCM replacement, setup, and programming.