DTC Descriptor

DTC P1A6C: Starter/Generator Control Module Not Programmed

Circuit/System Description

The starter/generator control module (SGCM) monitors to detect internal fault. If a fault is detected, the appropriate DTC will set.

Conditions for Running the DTC

The SGCM has received a wake up signal.

Conditions for Setting the DTC

The SGCM has detected an internal fault.

Action Taken When the DTC Sets

The hybrid system is disabled.

Conditions for Clearing the DTC

The SGCM is successfully programmed.

Reference Information

Schematic Reference

Hybrid Controls Schematics

Connector End View Reference

Component Connector End Views

Description and Operation

Starter/Generator Description and Operation

Electrical Information Reference

    •  Circuit Testing
    •  Connector Repairs
    •  Testing for Intermittent Conditions and Poor Connections
    •  Wiring Repairs

Scan Tool Reference

Control Module References for Scan Tool Information

Circuit/System Verification

Caution: To help avoid personal injury, additional precautions must be taken prior to working on the generator control module or the generator starter. After removing the 36V battery cables from the generator battery, remove both engine wiring harness connectors from the generator control module. Wait at least 5 minutes and then remove the generator control module cover. Verify voltage levels at all 36V, 12V, and 3-phase connections, are less than 3 volts using a DMM before proceeding.

Caution: To help avoid personal injury, be careful when working in the vicinity of the generator battery disconnect control module. Internal components will still be live, 36V potential, even when the cover has been opened or removed.

Verify that DTC P1A6C is not set as current.

If the DTC is set, program the SGCM. If the DTC resets, replace the SGCM.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

Control Module References for SGCM replacement, setup, and programming