• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
The battery energy control module (BECM) monitors the internal +5V reference for a out of range condition.
The engine is running, and the 12V input l to the BECM is greater than 9 volts.
The BECM detects the internal +5V reference circuit is less than 4.7 volts for greater than 3.7 seconds.
The DTC sets, does not affect hybrid operation.
The BECM detects the internal +5V reference circuit is greater than 4.7 volts.
Hybrid Energy Storage Schematics
Generator Battery Carrier Description and Operation
Control Module References for scan tool information
J 35616 GM Approved Terminal Test Kit
Caution: To help avoid personal injury, additional precautions must be taken prior to working on the generator control module or the generator starter. After removing the 36V battery cables from the generator battery, remove both engine wiring harness connectors from the generator control module. Wait at least 5 minutes and then remove the generator control module cover. Verify voltage levels at all 36V, 12V, and 3-phase connections, are less than 3 volts using a DMM before proceeding.
Caution: To help avoid personal injury, be careful when working in the vicinity of the generator battery disconnect control module. Internal components will still be live, 36V potential, even when the cover has been opened or removed.
Important: Use the following list to identify the appropriate terminals to test:
• | J-35616-65B for female terminals |
• | J-35616-64B for male terminals |
If the DTC occurs with P0AC0, P0AC1, P1A48 then the failure this diagnostic detects may have been the root cause of other current sensor DTCs that may have set.
⇒ | If less than specified value, replace the harness. |
⇒ | If greater than specified value, replace the harness. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
Control Module References for BECM replacement, setup, and programming