• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Accelerator Pedal Position (APP) Sensor 2 5-Volt Reference 1 Circuit | P0106, P0107, P0452, P0533, P0641 | P2127 | P0106, P0108, P0533, P0641 | -- |
Accelerator Pedal Position (APP) Sensor 1 5-Volt Reference 2 Circuit | P0651 | P2122 | P0335, P0651, P2135 | -- |
Air Conditioning (A/C) Refrigerant Pressure Sensor 5-Volt Reference 1 Circuit | P0106, P0107, P0452, P0532, P0641 | P0532 | P0641 | -- |
Engine Oil Pressure (EOP) Switch (if equipped) 5-Volt Reference 1 Circuit | P0107, P0452, P0522, P0532, P0641 | P0522 | P0641 | -- |
Fuel Tank Pressure (FTP) Sensor 5-Volt Reference 1 Circuit | P0106, P0107, P0452, P0532, P0641 | P0452 | P0641 | -- |
Manifold Absolute Pressure (MAP) Sensor 5-Volt Reference 1 Circuit | P0106, P0107, P0453, P0532, P0641 | P0106, P0107 | P0641 | -- |
Throttle Position (TP) Sensor 1 and 2 5-Volt Reference 2 Circuit | P0335, P0651, P2119 | P0122, P0222 | P0651 | -- |
Crankshaft Position (CKP) Sensor 5-Volt Reference 2 Circuit | P0651 | P0335 | P0651 | -- |
Camshaft Position (CMP) Sensor - Bank 1 Intake 5-Volt Reference 1 Circuit | P0106, P0107, P0452, P0532, P0641 | P0340, P0341 | P0106, P0108, P0533, P0641 | -- |
Camshaft Position (CMP) Sensor - Bank 1 Exhaust 5-Volt Reference 1 Circuit | P0106, P0107, P0452, P0532, P0641 | P0365 | P0106, P0108, P0533, P0641 | -- |
Camshaft Position (CMP) Sensor - Bank 2 Intake 5-Volt Reference 1 Circuit | P0106, P0107, P0452, P0532, P0641 | P0345 | P0106, P0108, P0533, P0641 | -- |
Camshaft Position (CMP) Sensor - Bank 2 Exhaust 5-Volt Reference 1 Circuit | P0106, P0107, P0452, P0532, P0641 | P0390 | P0106, P0108, P0533, P0641 | -- |
The engine control module (ECM) has a 5-volt reference buss for each 5-volt reference circuit. The circuits are called 5-volt reference 1 and 5-volt reference 2. Each bus provides a 5-volt reference for more than one sensor. A fault condition on one 5-volt reference circuit will affect the other 5-volt reference circuits connected to that reference bus. The ECM monitors the voltage on the 5-volt reference circuits.
• | DTCs P0601, P0602, P0603, P0604, P0605, P0606, P0607, P060D, P062F and P2610 are not set. |
• | The ignition is ON. |
• | The ignition voltage is greater than 5.23 volts. |
• | The DTCs run continuously when the above conditions are met. |
The ECM detects a voltage out of range condition on the 5-volt reference 1 or 2 bus for greater than 0.5 second.
DTC P0641 and P0651 are Type A DTCs.
DTC P0641 and P0651 are Type A DTCs.
• | The 5-volt reference 1 bus provides 5 volts to the following sensors: |
- | The manifold absolute pressure (MAP) sensor |
- | The fuel tank pressure (FTP) sensor |
- | The accelerator pedal position (APP) sensor 2 |
- | The engine oil pressure (EOP) switch |
- | The air conditioning (A/C) refrigerant pressure sensor |
- | The camshaft position (CMP) sensor |
• | The 5-volt reference 2 bus provides 5 volts to the following sensors: |
- | The APP sensor 1 |
- | The throttle position (TP) sensor 1 and 2 |
- | The crankshaft position (CKP) sensor |
• | It may be possible to locate the fault by disconnecting one component at a time from the affected 5-volt reference circuit while viewing the 5-Volt Reference circuit status parameter on the scan tool. The scan tool parameter will change from Fault to OK when the source of the fault is disconnected. If all 5-volt reference components have been disconnected and a fault is still indicated, the fault may exist in the wiring harness. |
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Control Module References for scan tool information
Important: A short to voltage on the signal circuit of certain components may cause this DTC to set.
⇒ | If less than the specified range, test for a short to ground on all the 5-volt reference circuits. If all circuits test normal, replace the ECM. |
⇒ | If greater than the specified range, test for a short to voltage on all the 5-volt reference circuits. If all circuits test normal, replace the ECM. |
⇒ | If not within the specified range when a component is connected, test the signal circuit for a short to voltage. If the circuit tests normal, replace the appropriate component. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for replacement, setup, and programming |