• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
The starter/generator control module (SGCM) monitors connector X2 terminals 15 and 16. When the connector is disconnected, the SGCM capacitors are electrically connected to a discharge resistor.
The engine is running.
36-volt output voltage greater than 10 volts and discharge resistance error signal is ON for 1 second.
Hybrid system is disabled.
Clears 30 seconds after cycle wakeup signal.
Possible cable open or SGCM internal problem.
Starter/Generator Description and Operation
Control Module References for scan tool information
⇒ | If the DTC resets, replace the SGCM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
Control Module References for SGCM replacement, setup, and programming