    • Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
    • Review Strategy Based Diagnosis for an overview of the diagnostic approach.
    •  Diagnostic Procedure Instructions provides an overview of each diagnostic category.

DTC Descriptors

DTC B3933 13: Air Conditioning (A/C) Evaporator Temperature Sensor Circuit Low Voltage

DTC B3933 14: Air Conditioning (A/C) Evaporator Temperature Sensor Circuit High Voltage

Diagnostic Fault Information

Circuit

Short to Ground

Open/High Resistance

Short to Voltage

Signal Performance

Evaporator Temperature Sensor Signal

B3933 13

B3933 14

B3933 14

--

Evaporator Temperature Sensor Low Reference

--

B3933 14

--

--

Circuit/System Description

The HVAC control module supplies the evaporator temperature sensor with a low reference circuit and 5-volt signal circuit. The HVAC control module determines the voltage drop across the sensor, which is proportional to temperature. When the refrigerant temperature is low the sensor resistance and voltage signal are high.

Conditions for Running the DTC

Ignition ON.

Conditions for Setting the DTC

The HVAC control module detects the evaporator temperature sensor signal circuit is less than 0.05 volts or greater than 4.9 volts.

Action Taken when the DTC Sets

    • The air conditioning (A/C) compressor will be disabled.
    • The default valve of -20°C (-4°F) will be substituted for the evaporator temperature sensor data by the HVAC control module.

Conditions for Clearing the DTC

    •  The DTC will become history if the HVAC control module no longer detects a failure.
    •  The history DTC will clear after 100 fault-free ignition cycles.

Reference Information

Schematic Reference

HVAC Schematics

Connector End View Reference

Component Connector End Views

Description and Operation

    •  Air Temperature Description and Operation
    •  Air Delivery Description and Operation

Electrical Information Reference

    •  Circuit Testing
    •  Connector Repairs
    •  Testing for Intermittent Conditions and Poor Connections
    •  Wiring Repairs

Scan Tool Reference

Control Module References for scan tool information

Circuit/System Testing

  1. Ignition OFF, disconnect the harness connector at the evaporator temperature sensor.
  2. Ignition OFF, test for less than 1 ohm between the low reference circuit terminal B and ground.
  3. If greater than the specified range, test the low reference circuit terminal for an open/high resistance. If the circuit tests normal, replace the HVAC control module.
  4. Ignition ON, test for 4.8-5.2 volts between the signal circuit terminal A and ground:
  5. If less than the specified range, test the signal circuit for a short to ground or open/high resistance. If the circuit tests normal, replace the HVAC control module.
    If greater than the specified range, test the signal circuit for a short to voltage. If the circuit tests normal, replace the HVAC control module.
  6. If all circuits test normal, test or replace the evaporator temperature sensor.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

    •  Air Conditioning (A/C) Refrigerant Low Temperature Sensor Replacement
    •  Control Module References for HVAC control module replacement, setup, and programming