🢒 Generator Control Module Coolant Pump Hose Replacement
Special Tools
J 38185
Hose Clamp Pliers
Removal Procedure
Drain the generator control module cooling system. Refer to
Generator Control Module Cooling System Draining and Filling
Remove the left headlamp. Refer to
Headlamp Replacement
Using
J 38185
Hose Clamp Pliers reposition the generator control module coolant pump hose clamp (1).
Remove the generator control module coolant pump hose (2) from the radiator surge tank air separator.
Remove the underhood junction block. Refer to
Underhood Electrical Center or Junction Block Replacement
Remove the coolant recovery reservoir. Refer to
Coolant Recovery Reservoir Replacement
Using
J 38185
Hose Clamp Pliers reposition the generator control module coolant pump hose clamp (1).
Remove the generator control module coolant pump hose (3) from the drive motor generator control module coolant pump.
Remove the generator control module coolant pump hose fastener (2) from the cooling fan shroud.
Remove the generator control module coolant pump hose (3) from the vehicle.
Installation Procedure
Install the generator control module coolant pump hose (3) to the vehicle.
Install the generator control module coolant pump hose fastener (2) to the cooling fan shroud.
Install the generator control module coolant pump hose (3) to the drive motor generator control module coolant pump.
Using
J 38185
Hose Clamp Pliers reposition the generator control module coolant pump hose clamp (1).
Install the coolant recovery reservoir. Refer to
Coolant Recovery Reservoir Replacement
Install the underhood junction block. Refer to
Underhood Electrical Center or Junction Block Replacement
Install the generator control module coolant pump hose (2) to the radiator surge tank air separator.
Using
J 38185
Hose Clamp Pliers reposition the generator control module coolant pump hose clamp (1).
Install the left headlamp. Refer to
Headlamp Replacement
Fill the generator control module cooling system. Refer to
Generator Control Module Cooling System Draining and Filling