Removal Procedure
- Disconnect the electrical connector from the
actuator.
- Remove the actuator screws from the HVAC control module.
- Remove the actuator from the HVAC control module.
Installation Procedure
- Align the flats on the actuator opening with
the flats on the door shaft.
Notice: Refer to Fastener Notice in the Preface section.
- Install the actuator screws to the HVAC module.
Tighten
Tighten the screws to 1 N·m (9 lb in).
- Connect the electrical connector to the actuator.
Important: Any time an HVAC module mode actuator or the HVAC control module is replaced,
the HVAC control module must be calibrated to ensure proper air distribution.
- Calibrate the mode door by simultaneously pushing the A/C and RECIRC buttons
on the HVAC control module three times each, within two seconds of initial push.
• | The A/C and RECIRC button LED's will flash while this calibration is taking
place. |
• | The calibration will take anywhere between 10 to 30 seconds depending
on battery voltage. |
• | The LED's will quit flashing when the calibration is complete. |
- Cycle the ignition and verify proper operation.