Special Tools
J 35749 Oil Pressure Socket
Removal Procedure
- Turn ignition OFF.
- Disconnect engine oil pressure (EOP) switch harness connector.
- Remove the EOP switch using the J 35749
.
Installation Procedure
- Apply RTV sealant (or equivalent) to the EOP switch threads.
Notice: Refer to Fastener Notice in the Preface section.
- Install the EOP switch.
Tighten
Tighten the engine oil pressure switch to 22 N·m (16 lb ft).
- Connect the EOP switch harness connector. Push in the connector until
a click is heard, then pull back to confirm a positive engagement.
- Check the oil level and fill if low.
- Start the engine and check for leaks.